When you buy polymer resin by the ton, the two documents that decide whether your production line runs smoothly or shuts down are the TDS and the COA. A Technical Data Sheet tells you what a grade is designed to do. A Certificate of Analysis tells you what the specific lot in your container actually measured. Buyers who confuse the two — or who skip them entirely — are the ones who end up with a translucent part that should have been clear, a seal that opens at 80 °C, or a quality complaint they cannot prove. This guide walks through both documents, the numbers that actually matter, and the red flags that should stop a purchase before it happens.
What Is a TDS (Technical Data Sheet)?
A TDS is the supplier's design specification for a grade. It lists the typical values a material is engineered to hit: melt flow rate, density, melting point, tensile strength, and — for functional resins — the properties that define the family, such as ethylene content in EVOH barrier resins or VA content in EVA copolymers.
Two things to remember about a TDS:
- It describes typical, not guaranteed, performance. The values are what the grade is built around, not a promise about your specific batch.
- It is a selection tool. You use it to compare grades, size a process window, and decide whether a material is even worth sampling.
What Is a COA (Certificate of Analysis)?
A COA is a per-lot test report. Every time a batch is made, the producer tests it and issues a document showing the actual measured values for that specific lot, tied to a lot number, production date, and sometimes a retest or expiry date.
Where the TDS is about the design, the COA is about the delivery. If your part fails, the COA is the piece of paper that proves what you were actually shipped. That is why it sits at the center of any serious incoming-quality program — and why we cover how to request and read one in our guide to sourcing resin from China.
TDS vs COA — What Each One Promises
| Aspect | TDS (Technical Data Sheet) | COA (Certificate of Analysis) |
|---|---|---|
| Question it answers | "What is this grade built to do?" | "What did this specific lot actually measure?" |
| Values shown | Typical / representative | Measured on your batch |
| Tied to a lot? | No — applies to the grade | Yes — lot number + date |
| Used for | Grade selection, process design | Incoming QC, complaint evidence |
| Issued when | With the grade (static) | With every shipment |
If a supplier hands you only a TDS and calls it a COA, that is your first red flag — they have not actually tested your lot.
6 Numbers on a COA Every Resin Buyer Should Verify
Most COAs carry a long list of properties. For incoming inspection you do not need all of them — you need the ones that move your process and your part. These six cover the vast majority of resin-buying failures:
| # | Parameter | Why it matters | What to check |
|---|---|---|---|
| 1 | Melt Flow Rate (MFR / MFI) | Defines how the resin fills the mold or extrudes. A 20% drift changes shrinkage, weld-line strength, and surface finish. | Within your agreed range and measured by the same standard (e.g., 190 °C/2.16 kg). |
| 2 | Density | Links to filler, copolymer ratio, and crystallinity. Off-density often means a substituted grade. | Matches the TDS typical within tolerance. |
| 3 | Melting / thermal point | Sets your barrel and seal temperatures. | Consistent with the grade's processing window. |
| 4 | Key functional value | The number that defines the family: VA content for EVA, ethylene content for EVOH, OTR for barrier films, graft ratio for tie-layer resins. | Exactly the property your application depends on. |
| 5 | Moisture / volatiles | High moisture in hygroscopic resins (PA, PET, some COP) causes splay, bubbles, and hydrolytic degradation. | Below the grade's maximum; demand dry handling for sensitive materials. |
| 6 | Lot, date, retest date | Your only thread back to the source if something fails. | Present, legible, and matching the container label. |
What a TDS Tells You About Processability
Beyond the COA checks, the TDS is where you plan the run. Three numbers drive most process decisions:
- MFR window — the acceptable range, not just the typical. A POE elastomer at the low end of its range behaves very differently in impact modification than one at the high end.
- Thermal stability — residence time and melt temperature limits. Push past them and you degrade the polymer, not just the part.
- Family-specific properties — for COC and COP it is glass-transition and birefringence; for barrier resins it is oxygen transmission rate; for adhesive copolymers it is adhesion to the target substrate.
Red Flags When Reviewing Supplier Documents
A document is only as good as the discipline behind it. Watch for these:
- TDS shows only "typical" with no range or test method. You cannot hold a supplier to a number they never defined.
- COA has no lot traceability — no lot number, no date, no production site.
- The COA does not name the grade or names a different one than you ordered.
- Values "pass" against the wrong method. MFR at 230 °C is not the same as at 190 °C; always confirm the standard.
- No method or standard cited at all. A number without a method is an opinion.
- Undated or recycled documents. A COA from last year does not describe this year's shipment.
A Simple Incoming-Inspection Workflow
You do not need a lab to use these documents well. A four-step routine catches most problems before resin ever reaches the hopper:
- Match the lot. Confirm the lot number on the COA equals the lot number on the container and the invoice. Mismatched paperwork is the single most common root cause of "we cannot reproduce the failure."
- Verify the six numbers. Run through the COA checklist above against your agreed specification, not against the TDS typical.
- Spot-check one functional property. Pick the number your application lives or dies on — OTR for a barrier film, adhesion for a tie layer, VA content for a sealant — and confirm it yourself when the part is critical.
- File both documents with the lot. TDS plus COA together are your defense if a complaint arrives six months later. A COA with no TDS, or vice versa, leaves a hole an auditor will find.
Documents in Regulated Markets
For food-contact, medical, or child-safe applications, the bar is higher. Buyers in these segments often need more than a COA: food-contact compliance statements, FDA or EU 10/2011 declarations, REACH and RoHS status, and lot-level traceability that survives an audit. Here the COA is not just QC paperwork — it is part of your own regulatory file. Insist on dated, lot-specific documents and a supplier who can reproduce them for any batch you ever shipped, because a generic or recycled certificate will not survive a customer audit.
TDS and COA Across Material Families
The "critical number" changes with the family, which is why a one-size checklist fails. A few examples from what we supply:
- EAA / EMAA adhesive resins — acid content and adhesion to the target substrate drive multilayer bond strength.
- EVOH barrier resins — ethylene content sets the OTR versus processability trade-off.
- COC / COP — glass-transition temperature and optical properties define medical and optical use.
- POE / TPV elastomers — MFR and comonomer type set impact and flexibility; see POE vs EPDM for the modifier choice, and our resin abbreviation guide for the abbreviations.
How POLYVALA Supplies TDS and COA
Every grade we supply ships against a current TDS, and every lot is backed by a per-batch COA so your incoming QC has a real reference, not a generic pdf. If you are qualifying a material or troubleshooting a failure, request the documents for the exact lot you plan to run — and if a number above looks off for your process, tell us the target and we will confirm the grade before you buy. See our sourcing and sampling guide for how MOQ, samples, and documentation work end to end.
Written by the POLYVALA Technical Team. Questions about a specific grade's TDS or COA? Browse our materials or contact us for the lot-specific documents.
Related reading: for the document side of sourcing, see 5 Myths Overseas Buyers Still Believe About Chinese Resin Suppliers - especially the section on why a COA is not a TDS.
Related Products
- Dow ENGAGE 8150 (POE elastomer)
- SK Chemical 3004 PRIMACOR (EAA)
- Kuraray E105B (EVOH)
- Chang Chun EVASIN EV2951F (EVOH)
- Dow 1601 Surlyn (ionomer)
- TOPAS 5013F-04 (COC)
About This Article
This guide is prepared by the POLYVALA technical team. All property values, test methods and compliance statements are drawn from manufacturer Technical Data Sheets (TDS) and recognized standards (ASTM, ISO). Figures must always be confirmed against the current official TDS and the lot-specific Certificate of Analysis (COA) before production qualification.
References
- Manufacturer Technical Data Sheets (TDS) for the grades referenced above.
- ASTM D1238 / ISO 1133 — Melt flow rate (MFR/MFR) of thermoplastics.
- ASTM D1505 / ISO 1183 — Density of plastics by the density-gradient technique.
- ASTM D638 — Tensile properties of plastics.
About this article
Written by the technical team at Shanghai Polyvala Plastics, a sourcing and compounding partner for specialty polymer buyers since 2013. We check grades against manufacturer TDS and lot-specific COA rather than marketing claims. Questions about a grade or an equivalent? Request the TDS and COA, or contact our application engineers for a line-specific recommendation.
Related reading: How to Read a Third-Party Polymer Test Report — the five fields to verify on a RoHS, REACH, PAHs or phthalates report.